Skip to main content

EnviroDek Epoxy Flooring Contractor in Atlanta, GA

Seamless glossy coated floor in a large commercial building

Urethane Cement Floors for Food and Beverage Processing

A commercial kitchen and a food processing plant look like the same flooring problem and they are not. A kitchen floor is a wet floor with grease on it. A processing floor is a wet floor that gets steam cleaned, caustic washed, thermally shocked and driven on, several times a day, every day.

Epoxy is an excellent material and it is the wrong one for that duty. The system that handles it is urethane cement, and the difference is worth understanding before a plant specifies a floor it will be replacing in two years. The kitchen case is covered separately in why commercial kitchen epoxy flooring is the best choice for your business.

What actually destroys a processing floor

Four mechanisms are at work and they compound one another.

  • Thermal shock. Hot product spills, steam cleaning and hot wash-down onto a floor chilled by refrigerated product or a cold room. The coating expands and contracts rapidly while the concrete beneath does so far more slowly, and the bond line carries that difference. A rigid thin film cannot absorb it and debonds.
  • Chemical attack. Caustic cleaners, sanitizers, acids from fruit, dairy and brine, and animal fats. Many of these attack ordinary resin systems directly, and lactic acid is particularly aggressive.
  • Mechanical abuse. Pallet jacks, forklifts, dropped equipment and steel wheels on a floor that is frequently wet.
  • Constant moisture, which affects both the coating and whatever is beneath it.

An epoxy floor in that environment usually fails at the thermal shock first, and once the bond is gone the chemical and mechanical exposure finishes it. The visible symptom is lifting at drains and doorways, which is where the duty is hardest.

What urethane cement is

Urethane cement, sometimes called urethane mortar or polyurethane concrete, is a hybrid: a cementitious material modified with urethane chemistry. It is placed as a mortar at substantial thickness rather than applied as a thin film. Three properties follow from that construction, and between them they are the whole reason it gets specified.

  • A coefficient of thermal expansion close to concrete’s. When the floor and the slab expand and contract at similar rates, the bond line is not carrying the difference, which is what allows it to survive thermal shock that destroys a rigid film.
  • Thickness. Placed at mortar thickness, it has the mass to absorb impact and the depth to be ground and repaired rather than replaced.
  • Tolerance of a damp substrate. These systems can generally be placed over concrete with a higher moisture content than a conventional epoxy will tolerate, which matters in a facility that cannot dry its slab out and cannot stop production for weeks. The broader moisture question is in the hidden cost of moisture under floors.

It is also available with antimicrobial additives, and it can be installed with the texture a wet process floor requires, which is coarser than most people expect.

Slope, drainage and the part that is not the floor

A processing floor is a drainage system that happens to have a surface on it, and treating it the other way round is the most common specification error. Water and wash-down have to leave continuously, or the floor stands wet and every other problem gets worse. That means positive slope to drains or trench drains, and more of it than a typical interior slab carries.

Where an existing slab does not have the fall, urethane cement can be placed at varying thickness to build it, which is one of the strongest arguments for the system in a renovation. A thin coating cannot create fall and a mortar can. Drain detailing is where these floors fail first, and it is covered specifically in trench drains and floor drains in coated floors.

Coving, which is a sanitation requirement

Integral cove base at every wall, equipment pad and column is standard in food processing, because a square internal corner is a place product and water collect and cannot be cleaned out. It is one of the first things an inspector looks at.

A cove formed as part of the floor system, in the same material, with a radius that a wash-down hose and a brush can actually clean, is what is expected. A separate applied base strip at the wall, or a silicone bead in the corner, is not the same thing and does not survive the same duty.

The same logic applies to equipment plinths. Equipment set directly on the floor creates an uncleanable edge; equipment set on a coved plinth does not.

Texture, because a wet floor is a slip hazard

Processing floors are wet by definition and staff work on them all shift, which makes traction a workplace safety item rather than a finish preference. Slip resistance comes from aggregate in the system, and the texture is deliberately coarse. That is a safety requirement with a maintenance consequence: a textured floor needs mechanical cleaning with the right equipment rather than a mop, which is why the cleaning program is specified alongside the floor. The general maintenance discipline is in concrete floor maintenance checklist for high traffic spaces.

Zoning the plant

Few plants need the same floor everywhere, and specifying one system throughout is how budgets get spent in the wrong place. Zoning is the single largest cost lever on a plant-wide project.

  • Wet processing, cook areas and wash-down zones are the urethane cement case, and they are where the money belongs.
  • Cold storage and freezers have their own requirement, because installation at low temperature and operation at low temperature are both constraints. That is covered in cold storage and freezer floor coatings.
  • Dry storage, packaging and warehouse areas are frequently well served by a conventional resin system at lower cost, as described in epoxy flooring for warehouses and production areas.
  • Transition zones between them need a detailed joint rather than an abrupt change in material, since the edge between two systems is where both start failing.

A floor plan marked up by zone, with the duty in each described, is the document that produces a sensible specification. Without it, a bidder has no choice but to price one system everywhere.

Installation in an operating plant

Most of these projects happen in a facility that cannot stop, and that constraint shapes the scope more than the material selection does. Phasing becomes part of the specification: which areas go out of service when, how long each zone is unavailable, and what the return to service time is. Urethane cement systems generally return to service faster than many alternatives, which is frequently the deciding factor rather than material cost.

Two items are settled early. Odor during installation, since some systems are considerably lower odor than others and a plant with product in it may have constraints. And the sequencing of equipment removal, since equipment that cannot be moved means detailing around it, which is slower and more expensive than an empty bay.

What belongs in the specification

A zone map with the duty in each area. The system, thickness and texture by zone. Slope and drainage, including whether the floor is building fall. Coving at walls, columns and plinths, with the radius. Drain detailing. The chemical exposure list, so the system can be checked against it. Installation temperature and return to service time. The cleaning program and the equipment it assumes. And the phasing plan. Our industrial work is on the commercial and industrial grade epoxy floors pages.

Frequently asked questions

Why does epoxy fail in a food processing plant?

Usually at thermal shock. Hot wash-down or steam cleaning onto a floor that has been chilled makes the coating expand and contract far faster than the concrete beneath it, and a rigid thin film cannot absorb that difference, so it debonds. Once the bond is gone, caustic cleaners, food acids and forklift traffic finish it.

What is urethane cement flooring?

A cementitious material modified with urethane chemistry, placed as a mortar at substantial thickness rather than as a thin film. Its thermal expansion is close to concrete’s, which lets it handle steam cleaning and hot spills, it has the mass to take impact, and it generally tolerates a damper substrate than conventional epoxy. It is the standard answer for wet processing areas.

Do we need the same floor system throughout the plant?

Rarely, and specifying one everywhere is how money gets spent in the wrong zones. Wet processing, cook and wash-down areas are the urethane cement case. Cold storage has its own installation and service temperature constraints. Dry storage and packaging are often well served by a conventional resin system at considerably lower cost.

What is integral coving and why does it matter?

Cove base formed as part of the floor system, in the same material, with a radius at every wall, column and equipment plinth. A square internal corner collects product and water and cannot be cleaned out, which is a sanitation failure. An applied base strip or a silicone bead is not equivalent and does not survive wash-down duty.

Can a processing floor be installed while the plant is running?

Usually yes, in phases, and the phasing belongs in the scope rather than being an afterthought. Settle which zones go out of service when, the return to service time for each, odor constraints if product is in the building, and whether equipment can be moved. Equipment that stays means detailing around it, which is slower than an empty bay.

Scroll to Top